Ambient Temperature Range
- 23° ± 5° C (73.4° ± 9° F)
Humidity
- 45 to 75 % RH at 23° ± 5° C (73.4° ± 9° F)
- 70 % RH, max.
- 90 % RH, Non-Condensing - Operating Humidity Range
Measuring Range
- 0.02 to 2,000 MΩ
- 0 to 300 V to AC Voltage Measuring Range
Operating Temperature
- 0° to 40° C (32° to 104° F)
Rating
- 1,000 V / 2,000 MΩ
- 100 V / 20 MΩ
- 250 V / 50 MΩ
- 500 V / 1,000 MΩ
- 500 V / 100 MΩ
Resistance
- 0.1 to 1 MΩ - Lower Limit of Measured ohms
- 0.5 to 50 MΩ - Central Scale Value
Storage Temperature
- -10° to 60° C (14° to 140° F)
Temperature Effect
- ≤ ± 0.7 % of Scale Length at Either the Infinite Scale Value or the Zero Scale Value when the Temperature is Changed from 0° to 40° C
- A Change in the Reading at an Ambient Temperature of 23° C (73.4° F) Must Not Exceed ± 5 %
Tolerance
- ± 10 % of Reading - Second Effective Measuring Range
- ± 10 % of, Max.
- ± 5 % of Reading - First Effective Measuring Range
- 0.7 %, Max.
- 1 mA (0 to 20 %) - Rated Measuring Current
- 12 mA - Max.
- 130 %, Max.