Specifications
Accuracy
- ± 0.3 % of Span (At Range more than Input 10 %)
Dissipation
- 12 VA at 200 Vac - Power Dissipation
- 150 mA at 24 Vdc - Current Dissipation
- 6 VA at 100 Vac - Power Dissipation
Frequency
- 0 to 10 kHz - Input Frequency
- 50 to 10,000 Hz - Span
Humidity
- 5 to 90 % RH, Non-Condensing
Insulation Resistance
- 100 MΩ at 500 Vdc between Input, Output, Power Supply & Ground
Mounting
- DIN Rail Mounting
- Wall Mounted
Output
- 0-100 mVdc
- 0-24 mA DC
- -10 to 10 Vdc
Power Supply
- 12-48 Vdc
- 85-264 Vac, 47 to 63 Hz
Power Supply Effect
- Less than ± 0.1 % of Span - Effect of Power Supply Voltage Fluctuation
Resistance
- 1 Kiloohm - Internal Load Resistance
- 2 to 250 kΩ - Load Resistance (Voltage)
- 200 ohms - Internal Load Resistance
- 510 ohms - Internal Load Resistance
- 750 to 15,000 ohms - Load Resistance (Current)
- More Than 10 kΩ - when Contact or Voltage Pulse (Input Resistance)
Response Time
- 3 seconds: less than 500 Hz Span, 63 % Response (10 to 90 %)
- 600 ms: more than 500 Hz Span, 63 % Response (10 to 90 %)
Supply Voltage
- 1,500 Vac/minute between Input, Output, Power Supply, Ground - Withstand Voltage
- 10 mV-20 Vdc - Span
- 12 Vdc - Power Voltage Supplied to Pulse Generator
- 24 Vdc - Power Voltage Supplied to Pulse Generator
Temperature Effect
- Less than ± 0.2 % of Span for 10° C (18° F) Change - Effect of Change Ambient Temperature
Temperature Range
- 0° to 50° C (32° to 122° F)
Zero Offset
- 0 to 200 % - Zero Elevation (Current)
- -100 to 200 % - Zero Elevation (Voltage)