Accuracy
- ± 0.1 % of Span or ± 0.01 mV whichever is greater - DC Voltage
- ± 0.1 % of Span or ± 0.1 ohm whichever is greater - Resistance
- ± 0.1 % of Span or ± 0.1° C (± 0.18° F) whichever is greater - RTD Pt100
- ± 0.1 % of Span or ± 0.2° C (± 0.36° F) whichever is greater - RTD Ni100
- ± 0.1 % of Span or ± 0.5° C (± 0.9° F) whichever is greater - E, J, K, N, T, L, U Thermocouples
- ± 0.1 % of Span or ± 1.0° C (± 1.8° F) whichever is greater - B, R, S, Lr, W3 & W5 Thermocouples
- ± 1° C (± 1.8° F) - Cold Junction Compensation Accuracy (Thermocouples)
Ambient Temperature Range
- -40° to 60° C (-40° to 140° F)
Approvals & Certifications
- ATEX
- CE - EN 61326-1, EN 61326-2-3, EN 55011
- CSA - Intrinsically Safe Approval
- EMC
- FM
- IECEx
- KC - Korea Electromagnetic Conformity Standard. Class A
- RCM - EN 61326-1, EN 55011
- RoHS Conformity - EN 50581
Electrical Connectors
- 26 to 14 AWG (0.13 to 2.08 mm²) - Stranded Wire Size
Humidity
- 0 to 95 % RH, Non-Condensing - Ambient Humidity Limits
Isolation
- 1,500 Vac - Input/Output Isolation
Load
- 250 to 600 ohms - for Digital Communication
Mounting
- DIN Rail Mounting DIN EN 60715 - 35 mm
- Panel Mount
Power Supply Effect
- ± 0.005 % of Full Scale Per Volt
Resistance
- 0 to 7,000 ohms - Input Range
- 10 MΩ - Input Resistance (For Thermocouples, mV)
- 3 kΩ at Power-Off - Input Resistance (For Thermocouples, mV)
- 5 ohms - Input Lead Wire Resistance (For RTDs, ohm)
Response Time
- 1 to 60 seconds Programmable
RTD Type
- Ni100 as Per DIN 43760
- Pt100 as Per IEC 751
Sensor Protection
- Burn-Out: High & Low (NAMUR NE43 UpScale & Downscale) or Value within 3.5-23 mA
Sensor, Probe Connection
- 2-Wire RTD or ohm
- 3-Wire RTD or ohm
- 4-Wire RTD or ohm
- T/C AND mV - DC mV
Sensor, Probe Type
- B Thermocouple as Per IEC 584
- E Thermocouple as Per IEC 584
- J Thermocouple as Per IEC 584
- K Thermocouple as Per IEC 584
- Lr Thermocouple as Per GOST 3044-84
- L Thermocouple as Per DIN 43710
- N Thermocouple as Per IEC 584
- RTD
- R Thermocouple as Per IEC 584
- S Thermocouple as Per IEC 584
- T Thermocouple as Per IEC 584
- U Thermocouple as Per DIN 43710
- W3 Thermocouple as Per ASTM E988-90
- W5 Thermocouple as Per ASTM E988-90
Span - Minimum
- 10° C (18° F) - RTD Typicals
- 2.5 mV - DC Voltage
- 200° C (360° F) - Thermocouples
- 25 ohms - Resistance
Supply Voltage
- 13.8-35 Vdc - for Digital Communication
- 8-30 Vdc - for Intrinsically Safe Typical
- 8-35 Vdc - for Operation
Temperature Effect
- ± 0.05 % of Span or ± 0.05 ohm Per 10° C (18° F) whichever is greater - Resistance
- ± 0.05 % of Span or ± 0.05° C (± 0.09° F) Per 10° C (18° F) whichever is greater - RTD Typical
- ± 0.05 % of Span or ± 0.25° C (± 0.45° F) Per 10° C (18° F) whichever is greater - E, J, K, N, T, L, U Thermocouples
- ± 0.05 % of Span or ± 1.0° C (± 1.8° F) Per 10° C (18° F) whichever is greater - B, R, S, Lr, W3 & W5 Thermocouples
- ± 0.05 % of Span or ± 5 μV Per 10° C (18° F) whichever is greater - DC Voltage
Temperature Range
- -200° to 2,300° C (-328° to 4,172° F)