Measuring Range
- -40° to +100° C (-40° to +212° F)
Response Time
- Forced circulation (temperature variation: 63 %): 55 s
- Flange, forced circulation: 90 s
- Natural convection: 150 s
Installation Instructions
- Mounted indoors/outdoors, but not exposed to direct sunlight
Pressure
- Maximum 4 bar (60 psi/400 kPa)
Cable Connection
- 2-core, 0.5 mm² (20 AWG)
- shielded
- silicone sheath
Process Connection
- 3/4" NPT [(Taper), ANSI / ASME B1.20.1]
- R 3/4" [(BSPT), EN 10226], totally encapsulated
Certificates & Approvals
- CE, IEC Ex, FM, CSA, ATEX