Specifications
Design
- Flange with integral Diaphragm, which Requires hydraulic fluid to transmit Pressure to instrument.
Process Connection
- 1/2" to 1" per ASME /ANSI B16.5 (Diaphragm recessed)
Instrument Connection
- Capillary, 1/4" or 1/2" NPT Female
Suitable Pressure Ranges
- 200 inH₂O to Class300, depending on flange and Diaphragm size and process conditions
Available Options
- (Connections, materials, etc.) See Selection Guide (Over)
- Aggressive, highly viscous, crystallising or hot media
- Process industry
- Small flange process connections