Certifications & Approvals
Accuracy
- 1 % for Velocities ≥ 0.3 m/s (1 ft/s)
Flow Range
- ± 12 m/s (± 40 ft/s), Depending On Pipe Size Higher or Lower
Outputs
- 1x 4-20 mA, 1x Relay, 1x Pulse/Frequency
Inputs
- 2x Digital Inputs for Totalizer Start/Stop and Reset
Repeatability
- ± 0.25 % - Based on ISO 11631
Operating Temperature
- -10° to 50° C (14° to 122° F)
Storage Temperature
- -20° to 60° C (-4° to 140° F)
Power Supply
- 100-240 Vac @ 20 VA
- 11.5 - 28.5 Vdc @ 10 W
Pipe Size
- 12.7 mm to 10 m (0.5" to 394")
Communication
- Modbus RTU, Compatible with SIMATIC PDM
Display
- 240 x 160, Fully Graphical