Specifications
Measuring Range
- XPS-10: 0.3 to 10 m (1 to 33 ft)
- Standard XPS-15: 0.3 to 15 m (1 to 50 ft)
- XPS-15 F models: 0.45 to 15 m (1.5 to 50 ft)
- XPS-30: 0.6 to 30 m (2 to 100 ft)
Frequency
- XPS-10: 44 kHz
- XPS-15 (standard and F models): 44 kHz
- XPS-30: 30 kHz
Beam Angle
- XPS-10: 12°
- XPS-15 (standard and F models): 6°
- XPS-30: 6°
Ambient Temperature
- XPS-10: -40° to +95° C (-40° to +203° F)
- Standard XPS-15: -40° to +95° C (-40° to +203° F)
- XPS-15 F models: -20° to +95° C (-4° to +203° F)
- XPS-30: -40° to +95° C (-40° to +203° F)
Storage Temperature
- XPS-10: -40° to +95° C (-40° to +203° F)
- Standard XPS-15: -40° to +95° C (-40° to +203° F)
- XPS-15 F models: -20° to +95° C (-4° to +203° F)
- XPS-30: -40° to +95° C (-40° to +203° F)
Pressure
- XPS-10: 8 bar g (120 psig)
- XPS-15 (standard and F models): 8 bar g (120 psig)
- XPS-30: 0.5 bar g (7.25 psi g)
Weight
- XPS-10: 0.8 kg (1.8 lb)
- XPS-15 (standard and F models): 1.3 kg (2.8 lb)
- XPS-15 (standard and F models): 2 kg (4.4 lb)
- XPS-30: 4.3 kg (9.5 lb)
Power Supply
- Operation of transducer only with approved Siemens controllers
Material
- Standard: PVDF
- Flanged: PVDF with CPVC flange
- Option: PTFE face with CPVC flange
Color
- Standard: Blue
- XPS-15F: Gray
Process Connection
- XPS-10: 1" NPT or 1" BSPT
- XPS-15 (standard and F models): Standard: 1" NPT or 1" BSPT XPS-15F: 1" NPT
- XPS-30: 1.5" universal thread (NPT or BSPT)
Cable
- 2-Wire twisted pair/braided and foil shielded 0.5 mm² (20 AWG) PVC jacket
- XPS transducers can be fully immersed, are resistant to steam and corrosive chemicals, and can be installed without flanges.
- The XPS series offers versions for various measuring ranges up to 30 m (100 ft) and up to a max. temperature of 95 °C (203 °F).
- During operation, the EchoMax transducers emit acoustic pulses in a narrow beam.
- The level monitor measures the propagation time between pulse emission and its reflection (echo) to calculate the distance.