Ambient Temperature Range
- -20° to 60° C (-4° to 140° F) - for Storage Conditions
- -5° to 45° C (23° to 113° F) - for Operating Conditions
Approvals & Certifications
- EMC EN 61326-1 Class A, EN 61326-2-3, EN 61000-3-2, EN 61000-3-3
- RCM EN 61326-1 Class A
Cable Length
- 8.2 ft (2.5 m) - Power Cable
Communication
- Half-Duplex Bit Serial
- Modbus Protocol
- RS-232C (9-Pins D-sub)
- RS-485
Display
- 4-Digit LCD with Backlight
Enclosure Finish
- Gray (Steel-Blue) - Plating
- Off-White (Munsell 10Y7.5/0.5 or Equivalent) - Front Panel
Enclosure, Body Material
- Steel - Blue, for Indoor Use
Flow Rate
- 0.26 gpm (1 LPM) - Purge Gas
- 0.5 ± 0.25 LPM - Sample Gas
Humidity
- 90 % RH, Non-Condensing, max.
Input Signal
- 0-1 Vdc from an O₂ Sensor Input Section is Non-Isolated - Analog Input Signal
Load
- 100 kΩ min. for 0-1 Vdc - Permissible Load Resistance
- 550 ohms, Max.
Materials of Construction
- 304 Stainless Steel - Gas Inlet/Outlet & Sample Cell
- Neoprene Rubber - Sample Cell
- SUS316 - O₂ Sensor Sampling Cell
- Teflon Tube - Internal Piping
- Toaron Tube - Internal Piping
Measuring Range
- 0 to 20 ppm Min., 0 to 100 Vol %, Max.
- 0 to 200 ppm Min., 0 to 100 Vol %, Max.
- 0 to 5 Vol % Min., 0 to 25 Vol %, Max.
- 0 to 50 ppm Min., 0-10 Vol %, Max.
- 0 to 50 ppm Min., 0 to 100 Vol %, Max.
- 0 to 50 ppm Min., 0 to 5,000 ppm, Max.
- Dust: 100 µg/Nm³ or Less in Particle Size of 1 μm or Less
Mounting
- 19" Rack-Mounted with Slide Rail
NPT Inlet
- 1/4" NPT Female - Gas Inlet
NPT Outlet
- 1/4" NPT Female - Gas Outlet
Operating Temperature
- -5° to 45° C (23° to 113° F)
Output
- 0-1 Vdc, Non-Isolation - Analog Output
- 100 mA or Less - Transistor Output
- 4-20 mA DC, Non-Isolation - Analog Output
Power Supply
- 100-240 Vac - Voltage Rating
- 85-264 Vac - Allowable Range
Pressure Range
- psi: 0 to 1.45 (kPa: 0 to 10, bar: 0 to 0.1) or Less (Gas Outlet Side Should be Open to the Atmospheric Air)
Ratio
- ≤ 1:25 (Except O₂ Analyzer) - Measuring Range Ratio
- ≤ 1:5 (O₂ Analyzer) - Measuring Range Ratio
Relay Output
- 250 Vac / 2 A, Resistive Load - Relay Contact Output
Repeatability
- ± 0.5 % of Full Scale
- ± 1 % of Full Scale - for Range less than 0-50 ppm
Response Time
- Approximately 20 seconds (For 90 % Response)
- Within 60 seconds Including Replacement Time of Sample Gas (For 90 % of Full Scale Response)
Span & Zero Effect
- ± 1 % of Full Scale/Week - Zero Drift
- ± 2 % of Full Scale/Day for Range less than 0-50 ppm - Span & Zero Drift
- ± 2 % of Full Scale/Week - Span Drift
- ± 2 % of Full Scale/Week for Range Equal to or more than 50 ppm & less than 200 ppm - Zero Drift
Temperature Range
- 0° to 50° C (32° to 122° F)
Window Material
- CaF₂ - Infrared Ray Transmitting Window