Measuring Range
- 6 m (20 ft) model: 0.25 to 6 m (10 inch to 20 ft)
- 12 m (40 ft) model: 0.25 to 12 m (10 inch to 40 ft)
Outputs - mA/HART
- Range: 4-20 mA
- Accuracy: ± 0.02 mA
Accuracy
- ± the greater of 0.15 % of Range
- 6 mm (0.24 inch)
Update Time
- ≤ 5 s
- 4/20 mA/HART version ≤ 5 s at 4 mA
- PROFIBUS version ≤ 4 s at 15 mA current loop
Temperature Compensation
- Built-in to compensate over temperature range
Ambient Conditions
- Location: Indoor/outdoor
- Ambient temperature: -40° to +80° C (-40° to +176° F)
- Storage temperature: -40° to +80° C (-40° to +176° F)
- Relative humidity/ingress protection: Suitable for outdoor
- Installation category: I
- Pollution degree: 4
Medium Conditions
- Temperature at flange or threads: -40° to +85° C (-40° to +185° F)
- Pressure (vessel): 0.5 bar g (7.25 psi g)
Material (Enclosure)
- PBT (Polybutylene Terephthalate)
Degree of Protection
- Type 4X / NEMA 4X
- Type 6 / NEMA 6 / IP67 / IP68 enclosure
Cable Inlet
- 2 x M20 x 1.5 cable gland
- 2 x 1/2" NPT thread
- 1 x M20 x 1.5
- 1 x 1/2" NPT
Material (Transducer)
- Buna-N seal with ETFE (Ethylene Tetrafluoroethylene)
- PVDF (Polyvinylidene Fluoride)
Threaded Connection
- 2" NPT [(Taper), ANSI / ASME B1.20.1]
- R 2" [(BSPT), EN 10226]
- G 2", BSPP, EN ISO 228-1
Flange Connection
- 3 inch (80 mm) universal flange
Other Connection
- FMS 200 mounting bracket
- customer supplied mount
Interface
- Local: LCD display with bar graph
- Remote: Available via HART or PROFIBUS PA
Configuration
- Using Siemens SIMATIC PDM (PC)
- HART handheld communicator
- Siemens infrared handheld programmer
Power Supply
- 4-20 mA/HART: Nominal 24 Vdc with 550 Ω maxi- mum, max. 30 Vdc 4-20 mA
- PROFIBUS PA: 12, 13, 15, or 20 mA depending on programming (General Purpose or Intrinsically Safe version)
PROFIBUS PA
- 12, 13, 15, or 20 mA depending on programming (General Purpose or Intrinsically Safe version)
- Per IEC 61158-2
Certificates & Approvals
- CSAUS/C
- FM
- CE
- RCM
- Lloyd’s Register of Shipping
- ABS Type Approval
- ATEX II 1G Ex ia IIC T4 Ga
- Class I, Div. 1, Groups A, B, C, D
- CSA/FM
- Class II, Div. 1, Groups E, F, G, Class III T4
- SIR 13.0008X Ex ia IIC T4 Ga
- INMETRO Ex ia IIC T4 Ga
- FM Class I, Div. 2, Groups A, B, C, D T4
Intrinsically Safe Siemens Handheld Programmer
Approvals for Handheld Programme
- ATEX II 1GD / IECEx SIR 09.0073
- Ex ia IIC T4 Ga
- Ex iaD 20 T135° C
- FM/CSA Class I, II, III, Div. 1, Groups A, B, C, D, E, F, G, T6
Ambient Temperature
- -20° to 50° C (-5° to 122° F)
Interface
- Proprietary infrared pulse signal
Power
- 3 V lithium battery (non-Replaceable)