Fail-safe: Programmable as high, low, or hold (loss of echo) per NAMURNE43
Resolution
3 mm (0.12 inch)
Accuracy
3 m (10 ft) version: 10 mm (0.39 inch)
6 m (20 ft), 12 m (40 ft) version: ± the greater of 0.15 % of Range or 6 mm (0.25 inch) [valid from 0.25 m (0.82 ft)], ± 2 mm (0.08 inch) on ranges 4 m (13 ft) or less
Non-Repeatability
3 mm (0.12 inch)
Blanking Distance
0.2 m (0.66 ft)
Update Time
4 s
Temperature Compensation
Built-in to compensate over temperature range
Ambient Conditions
Location: Indoor/outdoor
Ambient temperature: Storage: -40° to +85° C (-40° to +185° F), Operating: -40° to +80° C (-40° to +176° F)
Relative humidity/ingress protection: Suitable for outdoor
Installation category: I
Pollution degree: 4
Beam Angle
10°
Medium Conditions
Temperature at flange or threads: -40° to +85° C (-40° to +185° F)