Accuracy
- ± 0.03 % of Calibrated Span ± 1 Count
- 10 % to 100 % of Calibrated Span
Alarm
- Alarm Acknowledge Button Press
Approvals & Certifications
- ATEX II 2 GD, Ex d IIC T6 Gb, Ex Tb IIIC T85° C Db Ta = -40° to 75° C
- CE
- CSA Class I, Div. 1, Groups B, C, D, Class II, Div. 1, Groups E, F, G, Class III, Div. 1, T6, Class I, Zone 1, Ex d IIC T6 Ta = -40° to 75° C
- FM Explosion-proof for use in Class I, Div. 1, Groups B, C, D, Class II, Div. 1, Groups E, F, G, Class III, Div. 1, T6, Class I, Zone 1, AEx d IIC T6 Gb Zone 21, AEx Tb IIIC T85° C Ta = -40° to 75° C
- IEC Ex d IIC T6 Gb, Ex Tb IIIC T85° C Db Ta = -40° to 75° C
Consumption
- 0.2 W, Max.
- 0.25 W, Max.
- 0.5 W, Max.
- 0.75 W, Max.
Display
- 14-Segment Alphanumeric Characters
- -9,999 to 99,999
- Alarm Indication: HI & LO Symbol is Displayed
- Backlight: White
- LCD Display Backlight
- Lower: Seven Characters 0.40" (10.2 mm) High
- Upper: 0.70", 7-Segment, Automatic Lead Zero Blanking
- Upper: Five Digits, 0,70" (17.8 mm) High
Electrical Connectors
- 12 to 22 AWG
- Screw Terminal
Enclosure Finish
- Corrosion Resistant Epoxy Coating
Enclosure, Body Material
- Explosion-proof Die Cast Aluminum with Glass Window
Environmental Protection
- Explosion-proof
- IP66
- IP68
- NEMA 4X
- NEMA 7
- NEMA 9
Frequency
- 2 to 128 Hz - Pulse Ouput
- 64 dB at 50/60 Hz - Normal Mode Rejection
Function
- Linearization
- Live Input Calibration
- Password Protection
- Programmable Exponent
- Square Root
Humidity
- 0 to 90 % Non-Condensing Relative Humidity
Input
- 2 A, Max.
- 4-20 mA Loop-Powered
K-Factor
- Programmable from 0.0001 to 99999 - Pulse Output
Mounting
- 1-1/2" to 2-1/2" NPS or DN 40 to 65 mm Pipe Mounting
- May be Mounted Directly to Conduit
- Pipe
- Wall Mounted
Operating Temperature
- -40° to 75° C (-40° to 167° F)
Programming
- Four Internal Pushbuttons when Cover is Removed
- Four SafeTouch through-glass buttons when cover is installed
- Front Panel ENTER Button & Resets Output & Screen Indication - Acknowledge
Pulse Range
- 250 ms at 2 Hz - max.
- 3.9 ms at 128 Hz - min. Pulse Width
- 31 ms at 16 Hz - Factory Default Pulse Width
Rating
- Isolated Open Collector: 30 Vdc at 150 mA - Max.
Resistance
- 150 ohms at 20 mA without Loop-Powered Backlight - Equivalent Resistance
- 300 ohms at 20 mA with Loop-Powered Backlight - Equivalent Resistance
Rotation
- 90° to 270° - Display Orientation
Storage Temperature
- -40° to 85° C (-40° to 185° F)
Supply Voltage
- 12 Vdc
- 24 Vdc
- 30 Vdc
- 9 Vdc
- 9-36 Vdc
Update Time
- Ambient -25° C: 1 second for 1 Update - Display Update Rate
Voltage Drop
- 3.0 Vdc at 20 mA without Loop-Powered Backlight - max.
- 6.0 Vdc at 20 mA with Loop-Powered Backlight - max.