Specifications
Current
- ≤ 1 mA at 200/400/420 Vdc - Permissible Current Leakage
- ≤ 10 μA at 50/90/160 Vdc - Permissible Current Leakage
- ≤ 2 µA at 8/40 Vdc - Permissible Current Leakage
- ≤ 5 µA at 25/30/70/160 Vdc - Permissible Current Leakage
- 100 mA DC - Rated Current
- 2 A AC - Rated Current
- 20 A AC - Rated Load Current
Enclosure, Body Material
- Flame Deterrent ABS Resin
Humidity
- 5 to 90 % RH, Non-Condensing
Input Signal
- 0 to 100 mA DC
- RTD
- Thermocouples
Mounting
- DIN Rail
- JIS Class D Grounding
- M4 Screw
Operating Temperature
- -10° to 60° C (14° to 140° F)
Operating Voltages
- 140-280 Vac - Max.
- 25-160 Vdc - Max.
- 8-160 Vdc - Max.
Response Time
- 3 Nanoseconds
- 5 Nanoseconds
Supply Voltage
- 100-800 V - Voltage Protection Level (Between Lines)
- 150-1,500 V - Voltage Protection Level (Between Ground)
- 20-1,200 V - Instrument Side Voltage Limit (Between Ground)
- 20-420 Vdc - Discharge Starting Voltage (Between Lines)
- 2-1,000 V - Instrument Side Voltage Limit (Between Lines)
- 30-420 Vdc - Discharge Starting Voltage (Between Ground)